Model: SP/110 e SP/110 Special : High Temperature Dyeing Machine (135°C) Working in air-pad
system
Modular construction of 1, 2, 4 or 6 individual
vessels. Coupling device in pairs 2 + 2 + 2 or in tandem 4 + 2. Reversible pump
for each kier.
Electric or steam heating. Dimensions of each vessels at customer’s request
(SP/110 MAX capacity 25 litres, SP/110 SPECIAL MAX capacity 50 litres).
Models used for samples laboratory dyeing and small production. Each autoclave
can be charged different type of materials as yarn bobbins, tops, narrow fabric,
hanks, fabric, etc.
Completely construction in INOX stainless steel. Kiers are working in
atmospheric pressure and also under pressure until a MAX of 135°C, pressure
4,5Bars.
Other Detail:
Programmator: The dyeing cycle is obtained by the microprocessor programmator.
All functions are in AUTOMATIC and MANUAL. Settings: heating and cooling
temperature and gradients, maintenance time, alarms, introductions, filling and
draining, etc. Time bath inversion timer that indicates the pump operations
(internal / external and vice versa).
Sampling Device: (Optional) capacity 300cc for each kier, complete of nr. 3
manual ball valves, (2 for bath circulation and 1 for drain) with safety device.
Auxiliary Products Introduction: A separate small addition tank to be provided,
equipped with a dosing pump, for transferring dissolved dyes and chemicals into
the main kier under atmospheric or pressurised conditions.
Technical Data:
Max kier’s capacity: SP/110: 25 litres, SP/110 Special: 50 litres
Main kier’s dimensions: SP/110:Ø int. 170mm – MAX working height 800mm, Ø
int. 200mm – MAX working height 700mm, Ø int. 215mm – MAX working height
510mm, Ø int. 250mm MAX working height 400mm
SP/110 Special: Ø int. 200, 220, 250mm – MAX working height 1020mm
Power supply: SP/110: (electric heating) from 4 to 8KW each kier (steam heating)
2KW each kier
SP/110 Special: 3,5KW each kier
Temperature range: from 20 to 135°C
Heating: SP/110: electric heating by resistance or steam, SP/110 Special: steam
Gradient: from 0,3 to 3°C
Cooling: water circulation
Water inlet pressure: from 1,5 to 4 Bars
Air inlet pressure: (filtered for valves and air-pad device) 6 Bars
Steam pressure: from 5 to 8 Bars
Steam power: 26Kg with heating gradient 9,9°C/min
Flow pump: SP/110: from 1,5KW (0-110 litres/min depending from working pressure)
to 3KW, (0-193 litres/min depending from working pressure). Reversible, 2800 Rpm
each kier., SP/110 Special: 3KW, (0-193 litres/min depending from working
pressure). Reversible, 2800 Rpm each kier.
Dosing pump: 0,37KW, 2 litre/min, 2800Rpm each kier
Number of kiers: SP/110: 1, 2, 4, or 6, SP/110 Special: 1, 2 or 4
|